General Information
- Project: WWTP and Thermal Drying of Sludge in Sant Julià de Lòria
- Location: Sant Julià de Lòria (Principality of Andorra)
- Design flow: 30,000 m3 / day
- Population: 100,000 inhabitants / eq
- O&M period: 2010-2025
- Thermal drying with a daily design capacity: 20,600 kg. H2O evap / d
- Thermal drying with a maximum hourly capacity: 1,300 kg. H20 evap / h
Key Aspects
Pretreatment:
- Coarse well with clamshell spoon, coarse grating, sieving, grit remover, degreaser, flow limitation to biological with rainwater tank
Secondary treatment:
- Biological treatment of activated sludge, with elimination of nitrogen and phosphorus by biological means. O2 / Recirc contribution. Sludge / Settling
Sludge treatment:
- Mechanical thickener and centrifugal dehydration
Various:
- Fat reactor
- Deodorization by chemical washing
- Reception and treatment of external sludge from septic tanks, cleaning of sewage network and external fats
- Sludge drying
- Reception of external sludge
- VOMM fluid bed drying
- Pelletized dry sludge storage.